FEATURES
Small size – Safety Agency approved – Metalized
Polypropylene
APPLICATIONS
EMI filters – Line bypass – Across the line – Antenna
coupling
Operating Temperature Range
-40°C to +110°C
Capacitance Tolerance
+
10% at 1 kHz, 20°C
CSA ENEC CQC UL
AC voltage
(50/60 Hz)
250/310 VAC 305 VAC 275 VAC
250/310
VAC
Tan δ
Dissipation Factor
at 1 kHz and 20°C
.1% Max
Capacitance Terminal to Terminal Terminal to Case
<0.33uF
15000 MΩ
>30000 MΩ at 100VDC
>5000 MΩ at 500VDC
Insulation Resistance
@20°C (<70% RH)for 1 minute
at 100VDC applied
>0.33uF
5000 MΩxuF
>30000 MΩ at 100VDC
>5000 MΩ at 500VDC
Self Inductance
<
1 nano-Henry per mm of lead spaci ng and lead length
Terminal to Terminal
C<.0068uF, 1500 VAC or 2121 VDC applied for 60 Seconds
C>.0068uF, 1000 VAC or 1768 VDC a pplied for 60 seconds
Cut-off current: 2A ac or 10mAdc
Current limiting resistance: 1Ω/V
Dielectric Strength
Terminal to case
2050VDC applied between the terminals and case for 60 Seconds
and 20°C
1000 hours at 110°C at 125% of rated voltage with once every hour the voltage is
increased to 1000 VAC for 0.1 seconds
Capacitance chan g e
<
10% of initially measured val ue
Dissipation Factor
<
1.0% at 1kHz
Life Expectancy
Insulation Resistance
>
100% of initially specified value (T-T)
>
3000 MΩ (Terminal to case)
500 Hours at 90 to 95% RH, 40C an d no voltage applied after which the fo llowing
voltage will be applied for 1 minute to each capacitor.
C<0.0068uF 1500VAC, C>0.0068uF 1075VAC
Capacitance chan g e
<
10% of initially measured val ue
Dissipation Factor
<
1.0% at 1kHz
Humidity test
Insulation Resistance
>
50% of initially specified value (T-T)
>
15000 MΩ (Terminal to case)
Impulse voltage
(24 pulses)
C<
1uF Vp=2.5kVDC
C> 1uF Vp=2.5kV √C
Capacitance temperatu re
coefficient
-200ppm/°C, +
100ppm/°C
Construction
Metallized Polyprop ylene film
Electrodes
Vacuum deposited Metal layers
Coating
Flame retardant Solvent resistant plastic case with epoxy end fill (UL94V-0)
Lead terminations
Lead free tinned copper leads